CA 461 is designed to spy and detect leakage in pumps and mixers. The amplifier is housed in a norm enclosure fitted for DIN-rail mounting. The unit is available in two executions, 24 VDC or 110-230 VAC supply.
To minimize the risk of false alarms the failure has to be detected for minimum time duration of 10 seconds. To simplify the mounting the unit is fitted with plug-in type of connectors.
Key characteristics
Leakage monitoring with 10 sec alarm delay
Wide resistance range, 0-100 kOhm
Wide temperature range -20 to 50 ºC (-4 to 122 ºF)
Relay output 250 VAC 3 ampere
Connection via plug in connectors
DIN-rail mounted
Technical specifications
Leakage detection treshold
< 100 kOhm
Alarm on delay
10 seconds
Ambient operating temperature
-20 to 50 ºC (-4 to 122 ºF)
Ambient storage temperature
-30 to 80 ºC (-22 to 176 ºF)
Degree of protection
IP 20, NEMA: Type 1
Housing material
PPO and PC
Mounting DIN Rail
35 mm
Installation category
CAT II
Pollution degree
2
Flame rate
V0 (E45329)
Humidity
0-95% RH non-condensing
Dimensions
108 x 58 x 35 mm (4.25 x 2.28 x 1.38 in.)
Power supply
16907010: 110-230 VAC
16907011: 18-36 VDC, SELV or Class 2
Fuse
Max 10 A
Terminal wire size
Use copper (Cu) wire only. 0.2 – 2.5 mm2 flexible core, stripped length 8 mm.