☏ +64 9 263 9867
  • 0Shopping Cart
Pacific Technologies
  • HOME
  • ABOUT
    • ABOUT US
    • SUPPORT
    • GROUP OF COMPANIES & BRANDS
  • SERVICES
    • DESIGN & BUILD
    • PIPES & FITTINGS
    • WASTE WATER PUMPS
    • WATER TREATMENT PLANTS
    • WATER PUMPS & ACCESSORIES
    • INSTRUMENTATION PROCESS TECHNOLOGIES
    • WATER & WASTE WATER TREATMENT SERVICES
  • PRODUCTS
    • KROHNE
      • FLOW MEASUREMENT
      • LEVEL MEASUREMENT
      • TEMPERATURE MEASUREMENT
      • PRESSURE MEASUREMENT
      • PROCESS ANALYTICS
      • WIRELESS COMMUNICATION
      • ACCESSORIES
    • METASPHERE
      • DATA VISUALISATION
      • CABLES & ACCESSORIES
      • POINT ORANGE IoT
      • POINT ORANGE 3G
      • POINT GREEN 3G
      • POINT BLUE 3G
      • ART SEWER – WASTEWATER LEVEL MONITORING
    • PULSAR/GREYLINE
      • FLOW
      • LEVEL
      • VOLUME
      • SAND IN OIL
      • PUMP CONTROL
      • SLUDGE BLANKET
      • PROCESS PROTECTION
      • DISCONTINUED PRODUCTS
    • OTT HYDROMET
      • METEOROLOGY & CLIMATOLOGY
      • HYDROLOGY INSTRUMENTS
      • DATA COLLECTION & SOFTWARE
      • SOLAR INSTRUMENTS
    • HACH
      • LAB METERS & PROBES
      • SENSORS & CONTROLLERS
      • LAB EQUIPMENT & SUPPLY
    • ITRON
      • FLOSTAR
      • INTELIS WATER METER
      • WATER METER INTERPRETER REGISTER
      • WATER ERT MODULE
      • OPENWAY RIVA 500W ERT MODULE
      • OPENWAY RIVA LEAK SENSOR
      • ITRON MOBILE RADIO
      • WATER MODULE
      • FDM WORKORDERS
    • CAPRARI
      • AERATORS
      • CONTROLS
      • DRAINAGE
      • HIGH FLOW LINES
      • MIXER
      • SEWAGE
      • SOLAR BOREHOLE PUMPS
      • SURFACE PUMPS
      • VERTICAL INLINE SHIFTS
    • STRONGCAST
      • AMR & AMI
      • VALVES
      • METER COUPLINGS
      • BALL VALVE KITS
      • WATER METER BOXES
      • WATER METER BOX – ASSEMBLIES
      • DZR BRASS POLYETHYLENE FITTINGS
    • CLA-VAL
      • WATERWORKS
      • FIRE PROTECTION
      • FUELING
      • MARINE
      • ELECTRONICS
      • MINING & INDUSTRIAL
    • EMERSON/CUSTOM CONTROLS
      • VALVES, ACTUATORS & REGULATORS
      • KEYSTONE
      • VANESSA
      • BIFFI
      • NEOTECHA
      • ANDERSON GREENWOOD
      • CROSBY
      • CLARKSON
  • PROJECTS
  • NEWS
  • CONTACT
  • Menu Menu
Sensors (OPTIFLUX 6000 Sensor)

Sensors (OPTIFLUX 6000 Sensor)

The OPTIFLUX 6000 electromagnetic flow sensor is specifically designed to stay clean and sterile in compliance with the most stringent demands prevailing in the food & beverages and pharmaceutical industries.

There are no crevices, gaps or blind spots and the flow sensor offers full CIP/SIP possibilities. The flow sensor is conform FDA regulations for all wetted materials and is certified in accordance with EHEDG and 3A.

Categories: ELECTROMAGNETIC FLOW METERS, KROHNE
  • Description

Description

Sanitary and hygienic solution

    • Robust stainless steel housing for hygienic and aseptic operation
    • Fully suitable for CIP and SIP
    • Typical food & beverage and pharmaceutical process connections and insertion lengths

The OPTIFLUX 6000 electromagnetic flow sensor is specifically designed to stay clean and sterile in compliance with the most stringent demands prevailing in the food & beverages and pharmaceutical industries.
There are no crevices, gaps or blind spots and the flow sensor offers full CIP/SIP possibilities. The flow sensor is conform FDA regulations for all wetted materials and is certified in accordance with EHEDG and 3A.

 

The OPTIFLUX 6000 provides simple engineering, installation and commissioning. The flowmeter is available as a separate or compact version. Therefore the flow sensor can be installed in places difficult to access due to for example high temperatures or vibrations. The converter is also available in a stainless steel housing for applications when for example regular cleaning procedures with aggressive cleaning agents, may attack a standard polyurethane coating.In addition to weld-end connections, the OPTIFLUX 6000 offers a large number of other hygienic connections, including DIN 11851, DIN 11864, clamp and SMS. Because of its high accuracy, a precise measurement of the medium is possible enabling an accurate calculation of flows whether it is required for blending, dosing or batching. Furthermore, losses can be reduced to a minimum. It remains its accuracy in case of pulsating flows. And also when a medium has a low conductivity for example in case of glucose or fruit concentrates, the OPTIFLUX 6000 delivers an optimal performance.
Due to its reinforced liner the OPTIFLUX 6000 is an optimal solution for applications where high temperatures or vacuum impacts can occur. The OPTIFLUX 6000 hygienic construction is also available for larger diameters up to DN150 as volumes are increasing, and larger pipe sizes are needed with fast increase in the industrial production of beer, wine, milk and other beverages.

 

Highlights

    • Robust stainless steel housing for hygienic and aseptic operation
    • PFA liner reinforced with embedded stainless steel grid
    • Vacuum resistance
    • High form stability for good accuracy even with high pressures
    • Unique L-shaped gasket prevents expansion of gasket into measurement tube
    • Wide choice of electrode materials
    • Simple and effective CIP / SIP
    • Typical food and beverages and pharmaceutical process connections and insertion lenghts
    • Large diameter range up to DN150
    • All wetted materials FDA conform
    • EHEDG and 3A certified
    • Conductivity ≥ 1 μS/cm (for demi-water ≥ 20 μS/cm)
    • Process temperature up to 140°C

 

Industries

    • Food & Beverages
    • Pharmaceutical
    • Cosmetics

 

Applications

    • Exact blending, dosing and batching
    • Beverages including soft drinks, beer, wine and fruits juices
    • Milk and other dairy products
    • Beverages containing solids (for example yoghurt containing cereals)
    • Drugs, caustic sodas, acids, proteins, antibiotics
    • CIP media including acids and caustic solutions
  • For large-scale production plants with diameter up to DN150

Related products

  • Level transmitters

    Level transmitters

  • ULTRA SONIC FLOW METERS

    ULTRA SONIC FLOW METERS

  • IFC 100 Signal converter

    IFC 100 Signal converter

  • Sensors (OPTIFLUX 4000 Sensor)

    Sensors (OPTIFLUX 4000 Sensor)

© Pacific Technologies (New Zealand) Limited – Web Design Auckland