Description
Main benefits
- Plug-and-pump installation
Plug in without worrying about overheating. Built-in contactor and thermal sensors protects the motor from overheating.
Pumps with a built-in AquaTronic unit will electronically adjust for incorrect phase order, ensuring correct impeller rotation. - Reliable and trouble-free operation
A double outer casing and good heat convection allows continuous operation at low water levels – or dry running – without motor damage. The pump design, robust construction and premium materials ensure high wear resistance. - Serviceability
The modular design of the pump range saves cost by ensuring maximum pump availability with a smaller spare parts inventory.
The condition of a pump with a built-in AquaTronic unit can rapidly be checked without disassembly, using its service software. - Saves energy and the environment
The high-efficiency motor and hydraulics are combined with low friction bearings to reduce power losses. You achieve low total energy costs and minimize your carbon footprint. Environmentally safe white oil is used in the oil casing for easy inspection of seal conditions.
Product information
Submersible drainage center-line pump XJC 110 – 50Hz
Models
XJC 110 ND medium head 3-phase |
XJC 110 ND AT* medium head 3-phase |
XJC 110 HD high head 3-phase |
XJ 110 HD AT* high head 3-phase |
Weight: 80 kg (without cable) |
*AquaTronic: Built in electronic pump control.
Specification
Electric submersible pump
Maximum submergence | 20 m |
Protection class | IP 68 |
Max. temperature of pumped medium at max. power input and continuous duty | 40ºC |
Max. medium density | 1.100 kg/m3 |
pH of the pumped medium | 5-8 |
Strainer hole | 7.5 x 22 mm |
Max number of starts | 30/hour |
Motor rating P2 | 11.8 kW |
Speed | 2920 rpm |
Power cable | 20 m type S1BN8-F |
Starting Method and Motor Protection
XJC 110 AT: Soft start (400 V) is built in with the AquaTronic unit, where three thyristors reduces start current to three times the nominal current. Here two relays ensure correct motor rotation. The AquaTronic unit monitors motor temperature, by use of NTC thermistors built into stator windings, and stops the motor at high temperature. It will also stop the motor at high amperage or if a phase is missing.
XJC 110: Direct on line start with built in contactor. Pumps to be used with VFD or 1000 V must have terminal block instead of contactor. Thermal switches (140 °C, ±5) built into the stator windings are connected to the contactor and stop the pump at high temperature.
Discharge Connections
3” (standard ND), 4” (standard ND) , 6” (standard LD) hose connections |
3”, 4”, 6″ G/B.S.P. threaded connections |