Description
Main benefits
- Plug-and-pump installation
Plug in without worrying about overheating. Built-in contactor and thermal sensors protects the motor from overheating.
Pumps with a built-in AquaTronic unit will electronically adjust for incorrect phase order, ensuring correct impeller rotation. - Reliable and trouble-free operation
A double outer casing and good heat convection allows continuous operation at low water levels – or dry running – without motor damage. The pump design, robust construction and premium materials ensure high wear resistance. - Serviceability
The modular design of the pump range saves cost by ensuring maximum pump availability with a smaller spare parts inventory.
The condition of a pump with a built-in AquaTronic unit can rapidly be checked without disassembly, using its service software. - Saves energy and the environment
The high-efficiency motor and hydraulics are combined with low friction bearings to reduce power losses. You achieve low total energy costs and minimize your carbon footprint. Environmentally safe white oil is used in the oil casing for easy inspection of seal conditions.
Product information
Submersible drainage center-line pump XJC 50 – 50Hz
Models
XJC 50 ND medium head 3-phase |
XJC 50 ND AT* medium head 3-phase |
XJC 50 LD high flow 3-phase |
XJC 50 LD AT* high flow 3-phase |
XJC 50 HD high head 3-phase |
XJC 50 HD AT* high head 3-phase |
Weight: 59 kg |
*AquaTronic: Built in electronic pump control as option.
Specification
Electric submersible pump
Maximum submergence | 20 m |
Protection class | IP 68 |
Max. temperature of pumped medium at max. power input and continuous duty | 40ºC |
Max. medium density | 1100 kg/m3 |
pH of the pumped medium | 5-8 |
Strainer hole | 7.5 x 22 mm |
Max number of starts | 30/hour |
Motor rating P2 | 5.6 kW |
Speed | 2930 rpm |
Power cable | 20 m type S1BN8-F |
Starting Method and Motor Protection
XJC 50 AT: Direct on line start (DOL 500-550 V) with built in AquaTronic unit, which automatically adjusts phase order by dual contactors, ensuring correct motor rotation.
Soft start is built in with the AquaTronic unit at 230-400 V, where three thyristors reduces start current to three times the nominal current. Here two relays ensure correct motor rotation.
The AquaTronic unit monitors motor temperature, by use of NTC thermistors built into stator windings, and stops the motor at high temperature. It will also stop the motor at high amperage or if a phase is missing.
XJC 50: Direct on line start with built in contactor. Pumps to be used with VFD or 1000 V must have terminal block instead of contactor. Thermal switches (140 ºC, ±5) built into the stator windings are connected to the contactor and stops the pump at high temperature.
Discharge Connections
3” (standard HD), 4” (standard ND), 6” (standard LD) hose connections |
3”, 4”, 6″ G/B.S.P. threaded connections |